A three-layer packaged structure is proposed for an extrinsic Fabry–Perot interferometer-based optical fiber sensor in order to produce high resolution for large strains. The resolutions of three data processing algorithms including interference frequency tracking, period tracking and phase tracking are investigated and compared. Laboratory tests indicate that the proposed sensor structure can measure a strain of up to ±120 000 µε (±12%) with resolution as high as 10 µε. The sensor prototype is insensitive to fiber misalignment, enabling the study of progressive structural failures with an integrated use of the three algorithms.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: