Key result
The proposed TRSA-Net multitask model achieved competitive segmentation performance and highly accurate quantification results on paired 2D echocardiography from the public CAMUS dataset.
Why the study?
Current 2D echocardiography research often ignores uncertainty estimation during joint LV segmentation and quantification, creating a need for a unified optimization method.
The proposed TRSA-Net model improves automated left ventricular segmentation and quantification on 2D echocardiography by jointly learning spatial correlations.
Supports AI tools for echo quantification in research; leaves open clinical adoption pending prospective validation.
Clinical workflow of cardiac assessment on 2D echocardiography requires both accurate segmentation and quantification of the Left Ventricle (LV) from paired apical 4-chamber and 2-chamber. Moreover, uncertainty estimation is significant in clinically understanding the performance of a model. However, current research on 2D echocardiography ignores this vital task while joint segmentation with quantification, hence motivating the need for a unified optimization method. In this paper, we propose a multitask model with Task Relation Spatial co-Attention (referred as TRSA-Net) for joint segmentation, quantification, and uncertainty estimation on paired 2D echo. TRSA-Net achieves multitask joint learning by novelly exploring the spatial correlation between tasks. The task relation spatial co-attention learns the spatial mapping among task-specific features by non-local and co-excitation, which forcibly joints embedded spatial information in the segmentation and quantification. The Boundary-aware Structure Consistency (BSC) and Joint Indices Constraint (JIC) are integrated into the multitask learning optimization objective to guide the learning of segmentation and quantification paths. The BSC creatively promotes structural similarity of predictions, and JIC explores the internal relationship between three quantitative indices. We validate the efficacy of our TRSA-Net on the public CAMUS dataset. Extensive comparison and ablation experiments show that our approach can achieve competitive segmentation performance and highly accurate results on quantification.
No takes yet. Share an insight, caveat, or question.
Cui et al. (2022) studied Cardiac assessment on 2D echocardiography. TRSA-Net was evaluated on Segmentation performance and quantification accuracy. The proposed TRSA-Net multitask model achieved competitive segmentation performance and highly accurate quantification results on paired 2D echocardiography from the public CAMUS dataset.