Why the study?
With the growing use of cerebral protection devices during TAVR, it remained unclear whether using these devices impacts procedural complexity and risk.
Does the Claret Sentinel embolic protection device increase the complexity and risk of transcatheter aortic valve replacement in patients undergoing transfemoral TAVR?
Does the Claret Sentinel embolic protection device increase the complexity and risk of transcatheter aortic valve replacement in patients undergoing transfemoral TAVR?
The use of a cerebral embolic protection device during TAVR increases procedural time and contrast volume but is not associated with increased risk of vascular complications or renal failure.
Answers are grounded in this paper and cite their sources.
CS-EPD use adds procedural demands in TAVR; leaves open whether protection justifies added complexity in routine practice.
Background There is a growing use of cerebral protection devices in patients undergoing transcatheter aortic valve replacement (TAVR). We aimed to analyze if the use of these devices itself has an impact on the complexity and the risk of TAVR. Methods Between February 2016 and July 2017, 391 patients underwent transfemoral TAVR with Medtronic CoreValve Evolut R (n = 196) or Edwards Sapien 3 (n = 195). In 39 patients, the Claret Sentinel™ embolic protection device (CS-EPD) was used. Prospectively collected data were retrospectively analyzed, comparing fluoroscopy/operation time, amount of contrast used, vascular events, and postprocedural renal function in TAVR patients with (n = 39) and without (n = 352) CS-EPD. Results The CS-EPD was placed through the right radial (n = 35) or brachial (n = 4) artery. Procedural success rate defined as correct deployment and retraction of both filters was 94.9%. No device-related vascular complications occurred. TAVR patients with CS-EPD showed a significantly higher total operation time, total fluoroscopy time, and amount of used contrast (85.4 ± 39.3 vs. 64 ± 29.8 minutes, p = 0.002; 20.7 ± 9.3 vs. 13.7 ± 7 minutes, p ≤ 0.001; 133.7 ± 42.6 vs. 109.7 ± 44.5 mL, p = 0.001). Comparing the initial third of patients receiving a CS-EPD with the last third of CS-EPD cases, procedural time had decreased significantly (102.5 ± 34.9 vs. 67 ± 11.9; p = 0.002). There were no differences in postprocedural renal failure (p = 0.80). Conclusion Our data add evidence that the application of the CS-EPD is not associated with an additional risk for the patient. Although procedural time and amount of contrast are still higher when using the CS-EPD, there were no device-related complications or increased incidence of renal failure.
No takes yet. Share an insight, caveat, or question.
Deutsch et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: