Why the study?
Does measurement of the vascular pedicle width on portable chest X-rays correlate with fluid balance and pulmonary capillary occlusion pressure in mechanically ventilated critically ill patients?
Does measurement of the vascular pedicle width on portable chest X-rays correlate with fluid balance and pulmonary capillary occlusion pressure in mechanically ventilated critically ill patients?
Vascular pedicle width measured on portable chest radiographs is a reliable, non-invasive surrogate for assessing fluid overload in mechanically ventilated critically ill patients.
May aid noninvasive fluid overload assessment on portable radiographs in ventilated ICU patients; hypothesis-generating and requires prospective validation before practice change.
Background and Aims: Traditionally, invasive hemodynamic pressure measurements have been used to assess the volume status in critically ill patients. The vascular pedicle, as seen on chest radiographs, is the mediastinal silhouette of the great vessels. It is measured by drawing a perpendicular line from the point at which the left subclavian artery emerges from the aortic arch and measured across to the point at which the superior vena cava crosses the right main stem bronchus. We carried out this study to establish a correlation between the width of the vascular pedicle as seen on chest radiographs and daily fluid balance or pulmonary capillary occlusion pressure in mechanically ventilated, critically ill patients. Materials and Methods: In this prospective clinical study, 50 consecutive adult patients in a tertiary care, multidisciplinary intensive care unit underwent simultaneous measurements of the width of the vascular pedicle as seen on standardized, portable chest radiographs in the supine position and pulmonary capillary occlusion pressure measurements. Twenty-four hour fluid balance calculations were also recorded for each patient. Results: Vascular pedicle width measurements correlated closely with positive fluid balance, r = + 0.88, P 0.000. A Receiver Operating Characteristic curve demonstrated that a vascular pedicle width of 86.5 mm had a 100% sensitivity and an 80% specificity (area under the curve 0.823, 95% confidence intervals 0.714-0.932) for predicting fluid overload equal to and greater than 1200 ml. The correlation between pulmonary capillary occlusion pressures and width of the vascular pedicle was poor, r = 0.41, P 0.02. Conclusions: Our findings suggest that the vascular pedicle width on daily chest radiographs can be used to assess hypervolemia in the intensive care unit. Serial changes in the pedicle width could possibly be used to increase the accuracy of predictions.
No takes yet. Share an insight, caveat, or question.
Salahuddin et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: