Continuous-wave self-mode-locked operation of a chromium-doped YAG laser pumped by a continuous-wave Nd:YAG laser at 20 degrees C is described. We used both regenerative initiation and continuous-wave self-mode-locking techniques to generate nearly transform-limited pulses of 120-fs (FWHM) duration at 1.52 microm. The TEM(00) output power was as high as 360 mW. The output of this femtosecond source was tunable from 1.51 to 1.53 microm.
No takes yet. Share an insight, caveat, or question.
Sennaroğlu et al. (1994) studied this question.