Answers are grounded in this paper and cite their sources.
The effect of electrode density on safety was investigated with Li[Ni 0.8 Co 0.15 Al 0.05 ]O 2 (NCA) electrodes in the presence of 1.0M LiPF 6 EC:DEC (1:2 v/v ratio) using accelerating rate calorimetry (ARC). The densities of the electrodes were 1.6 g/cm 3 , 2.0 g/cm 3 , and 2.3 g/cm 3 , respectively. Denser electrodes showed inferior thermal stability compared to porous electrodes. ARC tests with ground electrode powder in the presence of EC:DEC (1:2 v/v) solvent, with and without LiPF 6 salt, show that the denser electrode has lower thermal stability because it contains less LiPF 6 . A charged NCA electrode in 0.7M LiBOB EC:DEC (1:2 v/v) electrolyte shows worse thermal stability than in 1.0M LiPF 6 EC:DEC (1:2 v/v) electrolyte. These results may be useful for researchers and engineers interested in designing safe electrodes using NCA positive electrode material.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: