The mechanism of collapse of tall steel moment-frame buildings is explored through three-dimensional nonlinear analyses of two 18-story steel moment-frame buildings under earthquake excitation. Both fracture-susceptible and perfect-connection conditions are investigated. Classical energy-balance analysis shows that only long-period excitation imparts energy to tall buildings large enough to cause collapse. Under such long-period motion, the shear-beam analogy alludes to the existence of a characteristic mechanism of collapse or a few preferred mechanisms of collapse for these buildings. Numerical evidence from parametric analyses of the buildings under a suite of idealized sawtooth-like ground-motion time histories, with varying period (T), amplitude (peak ground velocity, PGV), and duration (number of cycles, N), is presented to support this hypothesis. Damage localizes to form a quasi-shear band over a few stories. When the band is destabilized, sidesway collapse is initiated, and gravity takes over. Only one to five collapse mechanisms occur out of a possible 153 mechanisms in either principal direction of the buildings considered. Where two or more preferred mechanisms do exist, they have significant story-overlap, typically separated by just 1 story. It is shown that a simple work-energy relation applied to all possible quasi-shear bands combined with plastic analysis principles can systematically identify all the preferred collapse mechanisms.
No takes yet. Share an insight, caveat, or question.
Krishnan et al. (2012) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: