Why the study?
Current 18F-NaF PET/CT assessments of aortic valve microcalcification rely on end-diastolic or cardiac motion-corrected images, which remain affected by patient and respiratory motion.
Does triple motion correction improve quantitative measurements and correlation with CT calcification scores in 18F-NaF PET imaging of aortic valves in patients with aortic stenosis?
Does triple motion correction improve quantitative measurements and correlation with CT calcification scores in 18F-NaF PET imaging of aortic valves in patients with aortic stenosis?
Triple motion correction improves the quantification of 18F-NaF uptake and its correlation with CT calcification scores in patients with aortic stenosis.
Triple motion correction may enhance 18F-NaF quantification in aortic stenosis; leaves open prospective outcome validation.
Background Current 18 F-NaF assessments of aortic valve microcalcification using 18 F-NaF PET/CT are based on evaluations of end-diastolic or cardiac motion-corrected (ECG-MC) images, which are affected by both patient and respiratory motion. We aimed to test the impact of employing a triple motion correction technique (3 × MC), including cardiorespiratory and gross patient motion, on quantitative and qualitative measurements. Materials and methods Fourteen patients with aortic stenosis underwent two repeat 30-min PET aortic valve scans within (29 ± 24) days. We considered three different image reconstruction protocols; an end-diastolic reconstruction protocol (standard) utilizing 25% of the acquired data, an ECG-gated (four ECG gates) reconstruction (ECG-MC), and a triple motion-corrected (3 × MC) dataset which corrects for both cardiorespiratory and patient motion. All datasets were compared to aortic valve calcification scores (AVCS), using the Agatston method, obtained from CT scans using correlation plots. We report SUV max values measured in the aortic valve and maximum target-to-background ratios (TBR max ) values after correcting for blood pool activity. Results Compared to standard and ECG-MC reconstructions, increases in both SUV max and TBR max were observed following 3 × MC (SUV max : Standard = 2.8 ± 0.7, ECG-MC = 2.6 ± 0.6, and 3 × MC = 3.3 ± 0.9; TBR max : Standard = 2.7 ± 0.7, ECG-MC = 2.5 ± 0.6, and 3 × MC = 3.3 ± 1.2, all p values ≤ 0.05). 3 × MC had improved correlations (R 2 value) to the AVCS when compared to the standard methods (SUV max : Standard = 0.10, ECG-MC = 0.10, and 3 × MC = 0.20; TBR max : Standard = 0.20, ECG-MC = 0.28, and 3 × MC = 0.46). Conclusion 3 × MC improves the correlation between the AVCS and SUV max and TBR max and should be considered in PET studies of aortic valves using 18 F-NaF.
No takes yet. Share an insight, caveat, or question.
Lassen et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: