P-buried channel charge-coupled devices (CCDs) with a 100 Å sio2 and 1.2 Å Si3N4 dual gate insulator have been fabricated and radiation tested. The CCDs are 105-and 150-bit 4-phase linear shift registers with double-level polysilicon gates. Most of the experimental data is obtained on p-buried channel devices because design considerations suggest that the p-buried channel structure will have the greatest tolerance to ionizing radiation for devices with MNOS gates. Threshold shifts on the order of -1 volt/106 rad(Si) have been achieved at both 80°K and 300°K on CCDs which are operated continuously during the irradiation. The p-buried channel CCDs show essentially no degradation in pre-irradiation transfer efficiency up to doses of 106 rad(Si) without any change in the operating biases.
No takes yet. Share an insight, caveat, or question.
Saks et al. (1979) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: