This paper presents the development of a dual-axis gas gyroscope, whose working principle is based on the convective heat transfer and thermoresistive effect of lightly doped silicon. The working principle and the cross-sensitivity of the gas gyroscope are also analyzed. Experiments were performed to confirm the simulation results and good agreement has been achieved. The measured sensitivities for the X-axis and Y-axis were 0.107 mV deg−1 s−1 and 0.102 mV deg−1 s−1, respectively. Compared with a gyroscope of the same configuration but using tungsten as a sensing element, this gyroscope has 42 times greater sensitivity and one quarter the power consumption. These advantageous characteristics are inherited from the high TCR and high resistance of lightly doped p-type silicon. Nonlinearity and cross-sensitivity were measured to be smaller than 0.07% FS and 0.5% FS, respectively. The effect of acceleration on the sensitivity is 0.02 (deg s−1)/g and the measurement resolution based on sensitivity and noise analyses is 0.05 deg s−1. The relations between sensor performance, power consumption and ambient temperature were also realized.
No takes yet. Share an insight, caveat, or question.
Dau et al. (2006) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: