Key result
Coronary vasospasm was associated with a significantly higher frequency of reversible perfusion defects on ATP-SPECT imaging compared to patients without vasospasm (68% vs 36%, p=0.0027).
Why the study?
Does coronary vasospasm produce reversible perfusion defects on ATP-SPECT imaging in patients without significant coronary narrowing?
Observational (n=86)
Does coronary vasospasm produce reversible perfusion defects on ATP-SPECT imaging in patients without significant coronary narrowing?
Absolute Event Rate: 68% vs 36%
p-value: p=0.0027
Coronary vasospasm is a significant factor contributing to false-positive reversible perfusion defects on ATP-SPECT imaging in patients with angiographically normal coronary arteries.
May explain false-positive ATP-SPECT defects in angiographically normal arteries; hypothesis-generating pending prospective validation.
BACKGROUND: Adenosine triphosphate stress thallium-201 single-photon emission computed tomography (ATP-SPECT) is useful for diagnosing coronary artery disease (CAD), although sometimes false positive results are observed. It has not been established whether a coronary spasm is responsible for the false positive findings during ATP-SPECT. HYPOTHESIS: We investigated whether coronary spasm is one of the factors which produces reversible defects on ATP-SPECT. METHODS: Eighty-six patients (mean age: 62 y; 58 men) who underwent both spasm-provocation testing by coronary angiography and ATP-SPECT, were selected for the study. Patients with coronary narrowing (>30%), myocardial infarction, or heart failure were excluded. Patients were divided into 2 groups based on whether the spasm-provocation test result was positive (vasospastic angina [VSA] group, n = 46) or negative (non-VSA group, n = 39). RESULTS: The body mass index was lower in the VSA group than in the non-VSA group (p = 0.005). On ATP-SPECT imaging, any type of reversible defect was observed more frequently in the VSA group (68%) than in the non-VSA group (36%, p = 0.0027). Logistic regression analysis demonstrated that the presence of reversible defects was one of the factors accounting for the presence of coronary vasospasm (p = 0.0022, R2 = 0.172). CONCLUSIONS: The findings suggest that reversible defects on ATP-SPECT imaging are frequently present in patients with coronary vasospasm. Coronary spasm may be considered as 1 of the factors, which produce reversible defects on ATP-SPECT, observed in patients with chest symptoms and angiographically normal coronary arteries.
No takes yet. Share an insight, caveat, or question.
Teragawa et al. (2008) conducted an observational in Chest symptoms with angiographically normal coronary arteries (n=86). Positive spasm-provocation test (coronary vasospasm) vs. Negative spasm-provocation test was evaluated on Presence of any type of reversible defect on ATP-SPECT imaging (p=0.0027). Coronary vasospasm was associated with a significantly higher frequency of reversible perfusion defects on ATP-SPECT imaging compared to patients without vasospasm (68% vs 36%, p=0.0027).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: