PURPOSE: To correlate clinical results to magnetic resonance imaging (MRI) and arthroscopy after cryopreserved nontissue-antigen-matched meniscal transplantations. TYPE OF STUDY: Blinded; the observers were blinded for each others' assessment. MATERIALS AND METHODS: Sixteen consecutive patients were included in the protocol. First, clinical evaluation and MRI were performed. Second, within 24 hours, arthroscopy was performed. RESULTS: The clinical results showed better correlation between clinical results and arthroscopy than between clinical results and MRI. In the present study, MRI was not beneficial in evaluating meniscal transplants. CONCLUSIONS: Using more sophisticated MRI techniques, the correlation between clinical results, arthroscopy, and MRI could probably be improved.
No takes yet. Share an insight, caveat, or question.
Arkel et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: