Answers are grounded in this paper and cite their sources.
The interference between a uniform reference wave and a speckle object wave results in variable fringe contrast and background level. Taking these variations into account, we optimize system parameters of phase-shifting speckle interferometry. The results show that the optimal reference intensity should always be equal to one fourth of the detector’s saturation level. The optimal reference to the object-intensity ratio shows an increase from one up to, in most practical cases, six as a chosen interference dynamic range increases from its minimum value. The dependence of a maximal fraction of acceptable measurements on the dynamic range is calculated. Numerical examples indicate that we may hope for a readout accuracy in the range of 1/50th to 1/100th of a fringe period and still cover more than half of the image area with acceptable data. These data are taken without spatial averaging and have maximum resolution.
No takes yet. Share an insight, caveat, or question.
Slettemoen et al. (1986) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: