Key result
Biosimilar enoxaparin was equivalent to reference enoxaparin, with the 95% CI of the ratio of geometric least squares means for anti-FXa Amax at 94.6%-105.9%, falling within the 80%-125% range.
Why the study?
Does a single 100 mg subcutaneous dose of biosimilar enoxaparin demonstrate pharmacokinetic and pharmacodynamic equivalence to reference enoxaparin in healthy volunteers?
RCT (n=46)
Double-blind
Randomized
Does a single 100 mg subcutaneous dose of biosimilar enoxaparin demonstrate pharmacokinetic and pharmacodynamic equivalence to reference enoxaparin in healthy volunteers?
A biosimilar enoxaparin manufactured by Rovi demonstrated pharmacokinetic and pharmacodynamic bioequivalence to the reference drug Clexane in healthy volunteers.
Answers are grounded in this paper and cite their sources.
Supports biosimilar enoxaparin as interchangeable alternative; confirms PK/PD equivalence and extends biosimilar evidence.
Purpose: To demonstrate the pharmacokinetic/pharmacodynamic (PK/PD) equivalence of a biosimilar enoxaparin to the reference drug, and to assess its safety and tolerability in healthy volunteers. Patients and methods: A randomized, double-blind, crossover, 2-sequence, single-dose study was conducted in healthy volunteers of both sexes. Participants were sequentially and randomly administered single subcutaneous injections of enoxaparin 100 mg manufactured by Rovi (test; Madrid, Spain) and Clexane ® (enoxaparin 100 mg manufactured by Sanofi, reference) separated by a 1-week washout period. The primary PK/PD variables were maximum activity (A max ) and area under the effect curve from time 0 to the last measured activity (T) (AUEC 0–T ) and AUEC from time 0 to infinity (AUEC 0–inf ) of anti-FXa activity, and A max and AUEC 0–T of anti-FIIa activity. Secondary variables were A max and AUEC 0–T , AUEC 0–inf of tissue factor pathway inhibitor, and the ratio of AUEC 0–T anti-FXa to anti-FIIa activity. Biosimilarity would be shown when the 95% CI of the ratio of geometric least squares means (95% CI RGLSMs) of primary PK/PD parameters fell within the standard range of bioequivalence, ie, 80%–125%. Results: The study sample consisted of 46 volunteers (33 males) aged 18–44 years and with body mass index ranging from 19.0 to 31.1 kg/m 2 . Three subjects did not complete the study. The curves of anti-FXa, anti-FIIa and tissue factor pathway inhibitor activities corresponding to administration of the test and reference products were comparable. The 95% CI RGLSMs of A max , AUEC 0–T and AUEC 0–inf for anti-FXa activity were 94.6%–105.9%, 99.8%–108.0% and 100.0%–108.6% respectively; A max and AUEC 0–T for anti-FIIa activity were 94.7%–112.6% and 90.9%–117.9% respectively. In addition, the 95% CI RGLSMs of all secondary variables fell within the range 80%–125%. The incidence and types of adverse events after administration of the test and reference drugs were similar. Conclusion: The results conclusively showed that the enoxaparin manufactured by Rovi is equivalent to the reference enoxaparin in all primary and secondary PK/PD parameters, as required by the European Medicines Agency to grant marketing authorization to a biosimilar low molecular-weight heparin.
No takes yet. Share an insight, caveat, or question.
Núñez et al. (2018) conducted an RCT in Healthy volunteers (n=46). Biosimilar enoxaparin sodium vs. Reference enoxaparin (Clexane) 100 mg was evaluated on Maximum activity (Amax) of anti-FXa activity (Ratio of geometric least squares means, 95% CI 94.6-105.9). Biosimilar enoxaparin was equivalent to reference enoxaparin, with the 95% CI of the ratio of geometric least squares means for anti-FXa Amax at 94.6%-105.9%, falling within the 80%-125% range.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: