A time difference method to conveniently measure the phase shift between output wavelength and intensity of distributed feedback laser diodes (DFB-LDs) was proposed. This approach takes advantage of asymmetric absorption positions at the same wavelength during wavelength increase and decrease tuning processes in the intensity-time curve by current modulation. For its practical implementation, a measurement example of phase shift was demonstrated by measuring a time difference between the first time and the second time attendances of the same gas absorption line in the intensity-time curve during one sine or triangle modulation circle. The phase shifts at modulation frequencies ranging from 50 Hz to 50 kHz were measured with a resolution of 0.001π. As the modulation frequency increased the shift value increased with a slowed growth rate.