A poloidally viewing far infrared polarimeter diagnostic is being developed for the Alcator C-Mod tokamak, and will be used to determine the q-profile and to study density and magnetic field fluctuations. A three-chord version of what will eventually be up to a ten-chord system has been designed and fabricated and will be installed on C-Mod before the end of the current run period. Bench tests of a single chord mock-up of this system show acceptable noise levels for the planned measurements. We will discuss the analysis and experimental techniques used to diagnose and reduce noise sources.