An experimental investigation has been conducted to study the net flow direction induced by electrohydrodynamic forces in a wire-non-parallel plate electrode corona discharge. The experiments were conducted at two different locations of corona wire electrode for negative and positive applied voltage from 0 to 14 kV at atmospheric pressure and room temperature, where air was used as the working fluid. It was experimentally revealed that the net flow direction of electrohydrodynamically induced gas flow in a wire-non-parallel plate electrode system was changed depending on the location of the corona wire electrode relative to the grounded electrode position.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: