Shear Alfvén continua have been calculated for stellarators over a range of shapes and aspect ratios as a first step toward understanding Alfvén instability induced fast ion losses in such systems and possible means for minimizing these losses. Stellarators introduce strong poloidal/toroidal couplings in both |B| and the gρρ metric coefficient that can induce new continuum gap structures not present in axisymmetric tokamaks. Low field period (Nfp=2–3), low aspect ratio devices result in strongly coupled toroidal mode families (n=±n0,±n0±Nfp,±n0±2Nfp, etc.) that lead to helically coupled Alfvén gaps at lower frequencies and with wider gap structures than are the case for larger aspect ratio, higher field period stellarator devices.
No takes yet. Share an insight, caveat, or question.
Spong et al. (2003) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: