An integrative graphical method of designing a broadband TEM-mode power divider of N output ports is presented. Each branch of the divider's circuit consists of cascaded transmission-line segments, and the corresponding segments of each branch are connected by resistors to a common junction. These resistors absorb the reflected signals due to mismatch at any of the output ports; they are therefore isolated from one another. The symmetry of this circuit permits the use of the method of even- and odd-mode excitations at the output ports. It was found that the even-mode circuit is the same as for a stepped-impedance transformer, which is well known. The odd-mode circuit lends itself to the determination of the isolation resistors using the iterative graphical procedure on a Smith chart. Numerical values of the isolation conductance for dividers of bandwidths up to 10:1, the maximum input VSWR, and the minimum isolation among the output ports are given.
No takes yet. Share an insight, caveat, or question.
Yee et al. (1970) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: