Why the study?
Guideline-recommended echocardiographic estimation of right atrial pressure based on IVC size and respirophasic collapsibility suffers from operator- and patient-dependent variability.
Does a semi-automated echocardiographic tool for IVC edge-tracking improve the accuracy of non-invasive right atrial pressure estimation compared to guideline-based methods?
Does a semi-automated echocardiographic tool for IVC edge-tracking improve the accuracy of non-invasive right atrial pressure estimation compared to guideline-based methods?
A novel semi-automated echocardiographic tool using machine learning models (SVM and LM) improves the accuracy of non-invasive right atrial pressure estimation compared to standard guideline-based methods.
Answers are grounded in this paper and cite their sources.
ML models may improve echocardiographic RAP accuracy; hypothesis-generating and requires prospective validation before practice change.
The non-invasive estimation of right atrial pressure (RAP) would be a key advancement in several clinical scenarios, in which the knowledge of central venous filling pressure is vital for patients’ management. The echocardiographic estimation of RAP proposed by Guidelines, based on inferior vena cava (IVC) size and respirophasic collapsibility, is exposed to operator and patient dependent variability. We propose novel methods, based on semi-automated edge-tracking of IVC size and cardiac collapsibility (cardiac caval index—CCI), tested in a monocentric retrospective cohort of patients undergoing echocardiography and right heart catheterization (RHC) within 24 h in condition of clinical and therapeutic stability (170 patients, age 64 ± 14, male 45%, with pulmonary arterial hypertension, heart failure, valvular heart disease, dyspnea, or other pathologies). IVC size and CCI were integrated with other standard echocardiographic features, selected by backward feature selection and included in a linear model (LM) and a support vector machine (SVM), which were cross-validated. Three RAP classes (low < 5 mmHg, intermediate 5−10 mmHg and high > 10 mmHg) were generated and RHC values used as comparator. LM and SVM showed a higher accuracy than Guidelines (63%, 71%, and 61% for LM, SVM, and Guidelines, respectively), promoting the integration of IVC and echocardiographic features for an improved non-invasive estimation of RAP.
No takes yet. Share an insight, caveat, or question.
Mesin et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: