Anode acidification at the fibre/mortar interface challenges the durability of Fibre-Reinforced Cementitious Matrix (FRCM) composites in Impressed Current Cathodic Protection (ICCP) systems. This study examined the addition of 0.035–0.07 % graphene to FRCM composites, focusing on its role in phase formation, calcium leaching mitigation, and structural performance under electrochemical conditions. Graphene enhanced the formation of portlandite and C-S-H, densified the microstructure, and improved electrical conductivity, leading to reduced degradation and more uniform ion redistribution. Under current densities of 0.05–0.5 A/m 2 , graphene promoted the dissolution of unhydrated cement, rather than hydrated cement products, facilitating a continuous flow of cations and electrons. Thus, graphene-incorporated specimens exhibited delayed failure points and doubled the service life compared to controls. These findings demonstrated graphene's potential to reduce maintenance needs and material usage by up to 50 %, offering significant economic savings and sustainability benefits for ICCP systems.