A new static equivalent method using border PMU measurements is proposed to effectively retain various voltage and reactive power support characteristics of external network without real-time synchronous information of the entire external system. Based on the proposed method, a set of equivalent criteria is developed to determine whether the simplest and the most widely used PV/PQ equivalence is still appropriate. Based on the proposed equivalent method and criteria, we establish a new equivalent optimal reactive power flow model, which can achieve high calculation accuracy for interconnected power systems. The simulation results of the IEEE 39-bus system and an actual 661-bus system demonstrate the accuracy and effectiveness of the proposed method, criteria, and model.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: