Answers are grounded in this paper and cite their sources.
The magnetic properties, including ac core loss, dc hysteresis loss, eddy current loss, ac and dc permeability at 10 kG and 15 kG, and magnetic flux density at field strength 2500 A/m, of 17 heats of fully processed, continuous-annealed low-carbon electrical steels with grain diameter from 8.98 /spl mu/m to 23.25 /spl mu/m have been measured. Regression analysis is applied to find the relationships among magnetic properties, grain size, texture, and impurity. Grain size is the predominant factor to influence ac core loss, hysteresis loss, ac and de permeability, and magnetic flux density. In addition, carbon is deleterious to ac core loss and hysteresis loss at both inductions and dc permeability at 10 kG. Sulfur increases ac core loss and hysteresis loss at 15 kG. Nitrogen and oxygen decrease ac permeability at 10 kG and 15 kG, respectively. Soluble aluminum is detrimental to hysteresis loss and ac permeability at 15 kG. Texture component of (I/I/sub R/)/sub 2/22 is deleterious to hysteresis loss at 10 kG and magnetic flux density.
No takes yet. Share an insight, caveat, or question.
Chun‐Kan Hou (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: