Background and purpose - 32-mm heads are widely used in total hip arthroplasty (THA) in Scandinavia, while the proportion of 36-mm heads is increasing as they are expected to increase THA stability. We investigated whether the use of 36-mm heads in THA after proximal femur fracture (PFF) is associated with a lower risk of revision compared with 32-mm heads.Patients and methods - We included 5,030 patients operated with THA due to PFF with 32- or 36-mm heads from the Nordic Arthroplasty Register Association database. Each patient with a 36-mm head was matched with a patient with a 32-mm head, using propensity score. The patients were operated between 2006 and 2016, with a metal or ceramic head on a polyethylene bearing. Cox proportional hazards models were fitted to estimate the unadjusted and adjusted hazard ratio (HR) with 95% confidence intervals (CI) for revision for any reason and revision due to dislocation for 36-mm heads compared with 32-mm heads.Results - 36-mm heads had an HR of 0.9 (CI 0.7-1.2) for revision for any reason and 0.8 (CI 0.5-1.3) for revision due to dislocation compared with 32-mm heads at a median follow-up of 2.5 years (interquartile range 1-4.4).Interpretation - We were not able to demonstrate any clinically relevant reduction of the risk of THA revision for any reason or due to dislocation when 36-mm heads were used versus 32-mm. Residual confounding due to lack of data on patient comorbidities and body mass index could bias our results.
No takes yet. Share an insight, caveat, or question.
Tsikandylakis et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: