In this paper, we present experimental results of a small-model study, from which we plan to develop and apply a full-scale field-shaking system to reduce the screening-current-induced field (SCF) in the 800-MHz high-temperature superconducting (HTS) Insert (H800) of the MIT 1.3-GHz low-temperature superconducting (LTS)/HTS nuclear magnetic resonance magnet (1.3 G) currently under construction-the H800 is composed of three nested coils, each a stack of no-insulation (NI) REBCO double pancakes (DP). In 1.3 G, H800 is the chief source of a large error field generated by its own SCF. To study the effectiveness of the field-shaking technique, we used two NI REBCO DPs, one from Coil 2 (HCoil2) and one from Coil 3 (HCoil3) of the three H800 coils, and placed them in the bore of a 5-T/300-mm room-temperature bore LTS background magnet. The background magnet is used not only to induce the SCF in the DPs, but also to reduce it by the field-shaking technique. For each run, we induced the SCF in the DPs at an axial location where the external radial field BR> 0, and then, for the field shaking, moved them to another location where the external axial field Bz ≫ BR. Due to the geometry of H800 and L500, top DPs of three H800 coils will experience the considerable radial magnetic field perpendicular to the REBCO tape surface. To examine the effect of the field shaking on the SCF, we tested each NI REBCO DP in the absence or presence of a radial field. In this paper, we report 77-K experimental results and analysis of the effect and a few significant remarks of the field shaking.