Key result
Visual assessment of pancreatic fat deposition on CT showed high consistency with CT attenuation (kappa 0.925) and correlated with BMI and type 2 diabetes in mild to moderate grades.
Why the study?
The study was conducted to establish a simple, clinically useful visual assessment method for pancreatic fat deposition on CT images and evaluate its relationship with BMI and type 2 DM.
Does a visual grading system for pancreatic fat deposition on CT correlate with CT attenuation-based measurements, BMI, and type 2 diabetes?
Cross-Sectional (n=200)
No
Does a visual grading system for pancreatic fat deposition on CT correlate with CT attenuation-based measurements, BMI, and type 2 diabetes?
A simple four-scale visual grading system for pancreatic fat deposition on CT is consistent with quantitative attenuation-based measurements and correlates with BMI and type 2 diabetes in mild-to-moderate cases.
Visual grading may simplify pancreatic fat assessment on CT; leaves open its prognostic value in diabetes and obesity.
PURPOSE: To establish a simple and clinically useful method for the visual assessment of pancreatic fat deposition using computed tomography (CT) images, and to evaluate the relationship of the pancreatic fat deposition with body mass index (BMI) and type 2 diabetes mellitus (DM). MATERIALS AND METHODS: We used a four-scale grading system as the visual assessment criteria for pancreatic fat deposition using CT images. Pancreatic fat deposition was assessed for 200 patients and the results were compared with the CT attenuation-based assessment. In addition, the relationships of pancreatic fat deposition with BMI and type 2 DM were investigated. RESULTS: The visual and CT attenuation-based assessments were considered consistent. The results of the visual assessment suggested that mild and moderate pancreatic fat deposition correlated with BMI and presence of type 2 DM while severe fat deposition did not correlate with them. No correlation between pancreatic fat deposition and HbA1c level was found. CONCLUSION: The visual assessment criteria we used were consistent with CT attenuation-based assessment and may be useful for clinical application of pancreatic fat deposition. According to the visually assessment, mild or moderate pancreatic fat deposition correlated with BMI and the presence of type 2 DM, but severe fat deposition did not correlate with them.
No takes yet. Share an insight, caveat, or question.
Ookura et al. (2022) conducted a cross-sectional in Pancreatic fat deposition (n=200). Visual assessment of pancreatic fat deposition vs. CT attenuation-based assessment was evaluated on Intraobserver agreement of visual assessment for pancreatic fat deposition (pancreatic head) (weighted kappa 0.925, 95% CI 0.888-0.963). Visual assessment of pancreatic fat deposition on CT showed high consistency with CT attenuation (kappa 0.925) and correlated with BMI and type 2 diabetes in mild to moderate grades.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: