Chemical exposures in a university teaching lab were assessed using a tiered approach to modeling. Zero ventilation and well mixed room models estimated air concentrations of ethyl ether, n-hexane, and methylene chloride during distillation and extraction exercises. A simple, zero ventilation model determined that health risks from the ethyl ether exercise were minimum. N-hexane and methylene chloride exposures were evaluated with higher tiered, well mixed room models. An assumption that all of the solvent evaporated during the lab resulted in estimated n-hexane concentrations well below the occupational exposure limit. Methylene chloride concentration estimates using this approach were only one-half the occupational exposure limit, so the model was refined using information on the actual amount of solvent that evaporated. This resulted in a concentration estimate approximately one-fifth of the occupational exposure limit. Air sampling was done to evaluate model performance. Measured concentrations were higher than modeled concentrations by up to a factor of two but were still below applicable occupational exposure limits. The exposure models selected were deemed useful in the assessment of exposure acceptability in these labs.
No takes yet. Share an insight, caveat, or question.
Keil et al. (2006) studied this question.