Key result
Drug-coated balloons yielded similar MACE rates to drug-eluting stents in diabetic patients, but significantly lower target vessel revascularization (HR 0.41; 95% CI 0.18-0.95; P=0.038).
Why the study?
The study evaluated PCI outcomes for de novo stenosis with drug-coated balloons versus drug-eluting stents in patients with insulin-treated compared to non-insulin-treated diabetes mellitus.
Does drug-coated balloons reduce MACE compared to drug-eluting stents in diabetic patients with de novo coronary artery disease?
RCT (n=252)
Does drug-coated balloons reduce MACE compared to drug-eluting stents in diabetic patients with de novo coronary artery disease?
Drug-coated balloons provide similar MACE outcomes and potentially lower target vessel revascularization compared to drug-eluting stents in diabetic patients with de novo coronary lesions.
DCBs yield similar MACE with lower TVR versus DES in diabetics; extends randomized data to de novo lesions.
Background: We evaluated the outcome of PCI of de novo stenosis with drug-coated balloons (DCB) versus drug-eluting stents (DES) in patients with insulin-treated diabetes mellitus (ITDM) versus non-insulin-treated diabetes mellitus (NITDM). Methods: Patients were randomized in the BASKET-SMALL 2 trial to DCB or DES and followed over 3 years for MACE (cardiac death, non-fatal myocardial infarction [MI], and target vessel revascularization [TVR]). Outcome in the diabetic subgroup (n = 252) was analyzed with respect to ITDM or NITDM. Results: In NITDM patients (n = 157), rates of MACE (16.7% vs. 21.9%, hazard ratio [HR] 0.68, 95% confidence interval [CI] 0.29–1.58, p = 0.37), death, non-fatal MI, and TVR (8.4% vs. 14.5%, HR 0.30, 95% CI 0.09–1.03, p = 0.057) were similar between DCB and DES. In ITDM patients (n = 95), rates of MACE (DCB 23.4% vs. DES 22.7%, HR 1.12, 95% CI 0.46–2.74, p = 0.81), death, non-fatal MI, and TVR (10.1% vs. 15.7%, HR 0.64, 95% CI 0.18–2.27, p = 0.49) were similar between DCB and DES. TVR was significantly lower with DCB versus DES in all diabetic patients (HR 0.41, 95% CI 0.18–0.95, p = 0.038). Conclusions: DCB compared to DES for treatment of de novo coronary lesions in diabetic patients was associated with similar rates of MACE and numerically lower need for TVR both for ITDM and NITDM patients.
No takes yet. Share an insight, caveat, or question.
Seeger et al. (2023) conducted an RCT in De novo coronary artery disease with diabetes mellitus (n=252). Drug-coated balloons (DCB) vs. Drug-eluting stents (DES) was evaluated on MACE (cardiac death, non-fatal MI, and TVR) in non-insulin-treated diabetes mellitus patients (HR 0.68, 95% CI 0.29-1.58, p=0.37). Drug-coated balloons yielded similar MACE rates to drug-eluting stents in diabetic patients, but significantly lower target vessel revascularization (HR 0.41; 95% CI 0.18-0.95; P=0.038).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: