This paper describes a newly developed measurement and identification technique for synchronous machine parameters. The first part presents a technique to generate periodic broadband power signals with a controllable amplitude spectrum using a classic rectifier bridge. These signals are well suited to measure the frequency response function of large power systems using the fast Fourier transform. The broadband measurements are compared with the classical mono frequency measurements. The second part presents a frequency domain identification method taking into account the uncertainty on all the current and voltage measurements, and giving a confidence interval on the estimated synchronous machine parameters. As an illustration the d- and q-axis model of a 1.905 kVA/220 V micro-machine is identified.>
No takes yet. Share an insight, caveat, or question.
Beya et al. (1994) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: