Copper corrosion rate and corrosion products originating from acetic acid vapors have been studied using gravimetric, scanning electron microscopy, X-ray photoelectron spectroscopy, and argon-ion sputtering techniques. Copper specimens were exposed to the action of 10, 100, and 300 ppm acetic acid vapors generated in laboratory experiments at 40 and 80% relative humidity (RH) for a period of 21 days and at 30°C. The copper corrosion rate was in the range from 0.08 to 0.17 (mdd) for 40% RH and from 0.11 to 6.53 mdd for 80% RH. The main compounds found were cuprite copper hydroxide and copper acetate A corrosion process model is proposed in which copper acetate is formed from copper hydroxide present on the copper surface.
No takes yet. Share an insight, caveat, or question.
Bastidas et al. (2001) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: