This is the authors' abstract. We don't add key points for this paper.
THE ESTABLISHMENT and maintenance of a satisfactory artificial airway presents a major problem in the care of infants and children. Although tracheostomy is commonly used, it can produce serious complications at operation, during the period of intubation, and following decannulation.¹,²For 2½ years we have utilized nasotracheal tubes instead of tracheostomy in the management of a variety of airway and pulmonary problems. Materials and Methods A total of 116 children were intubated for a variety of problems which included: acute laryngotracheobronchitis, pneumonitis, status asthmaticus with respiratory failure, postoperative thoracotomy, and respiratory failure complicating nonrespiratory diseases such as encephalitis, renal failure, and exogenous obesity (Table 1). The mean age was 19 months with a range from 1 day to 14 years. Each child was seen by a pediatrician, an anesthesiologist, and an otolaryngologist. A consensus was reached that the airway problem could be handled best by nasotracheal intubation. Technique When
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
STRIKER et al. (1967) studied this question.