Answers are grounded in this paper and cite their sources.
A no-insulation (NI) pancake coil was wound with a 23 m long REBCO tape containing multiple ‘defects’, at which local critical currents are substantially lower (<80%) than the tape’s lengthwise average. During a charging test up to 60 A in a bath of liquid nitrogen at 77 K, the test coil showed ‘defect-irrelevant’ behaviors, i.e. coil terminal voltages and center fields in steady-state operations were barely discernible from those of an ideal ‘defect-free’ coil. Also, the critical current ( I c ) of the coil was measured to be 68 A, close to 72 A estimated from the measured I c angular dependency data of a defect-free sample tape that was used for construction of the coil. The results demonstrate a potential to build a pancake coil with REBCO tapes regardless of their defects, which may lead to a substantial reduction in the construction cost of high field NI REBCO magnets.
No takes yet. Share an insight, caveat, or question.
Hahn et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: