In order to measure the line integrated electron density on the International Thermonuclear Experimental Reactor (ITER), a vibration-compensated five-channel CO2 laser interferometer/polarimeter system is being developed. The design of the interferometer/polarimeter has been improved from the previous design, which used a CO2 laser (wavelength, λ=10.6 μm) and a CO laser (λ=5.3 μm), on the basis of experience gained with a dual CO2 system (λ=10.6 and 9.27 μm) on JT−60U. The JT−60U system gives good reliability for both interferometry and polarimetry operation. The performance of the dual CO2 laser is expected to meet the requirements for measurements on ITER (accuracy; 1%, time resolution; 1 ms).