Zero voltage switching (ZVS) is critical for reliable operation of standard current-fed parallel resonant inverters. Under steady-state conditions, ZVS can be achieved using common techniques such as a phase lock loop, a voltage controlled oscillator, and other integral controllers. However, during transient processes, achieving ZVS is not trivial for such controllers and consequently switch failure can occur. This paper proposes a dynamic ZVS method to solve the start-up problems by using a forced dc current. Start-up conditions are analyzed and complete dynamic ZVS control is achieved. If the ramp-up delay of practical dc power supplies is utilized, the start-up process can be controlled to be overshoot-free at no extra cost. The validity of this method is proven using both PSpice simulations and experimental results
No takes yet. Share an insight, caveat, or question.
Hu et al. (2006) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: