Why the study?
Are arterial pulse contour techniques interchangeable with bolus thermodilution for assessing changes in cardiac output in cardiac surgery patients?
Population
24 consecutive patients undergoing coronary surgery with cardiopulmonary bypass, without congestive heart…
Comparison
Cardiac output measurement using 5 arterial… vs Cardiac output measurement using 4-bolus…
Design
Cohort
Authors
Loading...
Pulse contour techniques should not replace thermodilution for tracking CO changes in cardiac surgery; leaves open need for device-specific validation.
Are arterial pulse contour techniques interchangeable with bolus thermodilution for assessing changes in cardiac output in cardiac surgery patients?
A novel trend interchangeability method demonstrates that five common arterial pulse contour techniques are not interchangeable with bolus thermodilution for tracking cardiac output changes during cardiac surgery.
Fischer et al. (2016) studied this question.