Dead-time and switch voltage drops represent the most important sources of distortion of the (average) output voltage in pulsewidth modulation inverters. Their effect is a function of the parameters of the drive system and of the operating conditions and is often intolerable in many drives applications, thus requiring a proper compensation strategy. Many techniques are implemented in industrial drives and reported in the literature, even very recently. Differently from standard approaches, the proposed methodology is based on a detailed physical model of the power converter (including output capacitance), described by a small set of parameters. A novel self-commissioning identification procedure is introduced, adopting multiple linear regression. The technique is tested on a commercial drive in comparison with state-of-the-art techniques. In addition, back electromotive force estimation improvements in a permanent-magnet synchronous motor sensorless drive system are shown to provide additional validation of the method.
No takes yet. Share an insight, caveat, or question.
Bedetti et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: