Demonstrates the feasibility of percutaneous closure of a mitral paravalvular leak using a retrograde transfemoral arterial approach without an arterio-venous wire loop.
Answers are grounded in this paper and cite their sources.
Single-case success extends technical options for retrograde mitral paravalvular leak closure; leaves open need for prospective safety and durability data.
Repeat surgery has usually been considered the first choice to solve paravalvular leaks of prosthetic valves, but it carries a high operative risk, a high mortality rate and an increased risk for re-leaks. Percutaneous closure of such defects is possible, and different approaches and devices are used for this purpose. For mitral paravalvular leaks, constructing an arterio-venous wire loop for delivering the closure device through an antegrade approach is the most commonly used technique. Transcatheter closure can also be performed through a transapical approach or retrograde transfemoral arterial approach. We present a case of 68-year-old man with a mitral paravalvular leak that was successfully closed using an Amplatzer(®) Duct Occluder II, via retrograde transfemoral arterial approach under three-dimensional transesophageal echocardiographic guidance, without the use of a wire loop. The initial attempt to cross the paravalvular defect was unsuccessful, but the obstacle was finally overcome by introducing complex interventional techniques.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2015) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: