Hourly values of relative humidity recorded at 75 stations across Canada were examined. Data were checked for possible discontinuities arising because of changes in procedures and instruments. It was found that the replacement of the psychrometer by the dewcel has produced a decreasing step in relative humidity at a number of stations. The historical records were closely examined to retrieve the dewcel installation date, and a procedure based on regression models was applied to determine if it corresponds to a significant step. Results show that there are more stations experiencing a dewcel step in the winter than in the summer. Examination of the trends also reveals that the step often accentuates the decreasing trends originally observed during winter and spring. However, significant steps taken into account, it appears that the relative humidity still decreased by several percent in the spring during 1953–2003 in western Canada. It seems that the southern and coastal stations are not as much affected by this change of instruments.
No takes yet. Share an insight, caveat, or question.
Wijngaarden et al. (2005) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: