A method is proposed for analysis of arbitrarily loaded lossy and dispersive nonuniform single or coupled transmission lines.In this method, the transmission lines are subdivided to several uniform sections, at first.Then the voltage and current distributions are obtained using second order step-by-step numerical integration (second order finite difference method).The accuracy of the method is studied using analysis of some special types of single and coupled transmission lines.
No takes yet. Share an insight, caveat, or question.
Mohammad Khalaj‐Amirhosseini (2006) studied this question.