Experimental characterization reveals an absolute photon detection efficiency of up to 4.5% in X-ARAPUCA devices for liquid argon detectors, indicating enhanced neutrino detection sensitivity.
The DUNE experiment will implement a photon detection system composed of X-ARAPUCA (XA) devices. These trap incoming VUV photons by internal reflection in a wavelength shifter light guide to be collected onto silicon photomultiplier arrays, sensitive to visible light. In the baseline design, dichroic filters are used to prevent photons from escaping. The configuration proposed for DUNE’s Vertical Drift (VD) (VD) module has been characterised in liquid argon for the first time using dedicated cryogenic setups developed at CIEMAT and INFN Naples. Additionally, several alternative configurations, based on the design optimisation studies of an R&D campaign, have been evaluated. The results show an efficiency of up to (4.5 ± 0.4)% at 4.5 V overvoltage, representing a significant improvement over previous XA implementations. Most notably, configurations without dichroic filters show an improvement of up to 18%, attributed to transmittance losses in the dichroic filters.
No takes yet. Share an insight, caveat, or question.
Botogoske et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: