Answers are grounded in this paper and cite their sources.
For the analysis of the 15 polycyclic aromatic hydrocarbons (PAH) classified as priority from the Scientific Committee on Food (SCF) and benzo[c]fluorene (BcL) assessed to be relevant by the Joint FAO/WHO Experts Committee on Food Additives (JECFA) in food, a sensitive analytical method is necessary. In the past, many methods were established for only the analysis of the 16 priority PAH recommended by the US Environmental Protection Agency (16 EPA-PAH) but not for the 15 SCF-PAH and BcL. Therefore, at the Max-Rubner-Institut, Federal Research Institute of Nutrition and Food in Kulmbach, Germany, an analytical method with a runtime of 72 min was developed. To shorten this runtime without a loss of separation, a Fast-GC/high resolution MS (HRMS) method with a runtime of only 25 min using a TR-50ms column (10 m x 0.1 mm x 0.1 microm) was created. The repeatability (n = 3) of spiked PAH concentrations in test-matrix tea ranged from 0.1 to 11%. The analytical parameters LOD (0.01-0.02 microg/kg) and LOQ (0.03-0.06 microg/kg) also in the test-matrix tea were determined. A good linearity for all PAH (R(2) >0.99) and averaged recoveries from 75 to 117% in the concentration range of 1-20 microg/kg were achieved.
No takes yet. Share an insight, caveat, or question.
Ziegenhals et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: