We describe a new, highly selective procedure for the determination of estradiol-17 beta in plasma. Samples are extracted with a micro-cellulose-coupled antiserum to estradiol-17 beta. Conversion of the extracted steroid to the bis(trimethylsilyl) ether is followed by gas chromatography/high-resolution mass spectrometry with selected ion monitoring. Precise quantification is achieved through the use of [2H3]estradiol-17 beta as internal standard.