Answers are grounded in this paper and cite their sources.
METHODS: This was a French prospective bicentric study. All patients with an indication for creation of a distal or proximal end to side AVF performed by supervised trainee were eligible. Follow-up was performed clinically and by Duplex scan at 6 weeks and 6 months post fistula creation. Primary endpoint was functional maturation at 6 weeks defined as successful use for dialysis via 2-needle cannulation in dialysis patients or a flow rate of ≥600 mL/min and a target vein diameter ≥6 mm for pre-dialysis patients. Overall functional success for dialysis patients was assessed as well. RESULTS: device and were followed for an average of 165 days. Median age was 61. Eleven patients (52%) were on dialysis at the time of implantation. AVFs were created with distal radial (N.=8), proximal radial (N.=5), brachial cephalic (N.=4) or brachial basilic (N.=4) arteries with 100% technical success . Functional maturation at 6-weeks was achieved in 81% (17/21). Functional success was 80% (12/15) with unassisted functional success of 67% (10/15) at 6 months for patients requiring dialysis at that time point. Two reoperations were performed within the device, one thrombectomy and one angioplasty, both were successful. Freedom from access-related interventions occurred in 71% (15/21) of the study population at 6-months. CONCLUSIONS: can successfully assist in achieving excellent results at the introduction of the device to a new center.
No takes yet. Share an insight, caveat, or question.
Hauguel et al. (2024) studied this question.