Heat capacities of molten polyethylene, polypropylene, poly‐1‐butene, polystyrene, and poly(methyl methacrylate) were measured over a wide range of temperature by using a differential scanning calorimeter. The upper limit of temperature was established for each polymer at about 10°K below the beginning of thermal decomposition. For poly‐1‐butene and poly(methyl methacrylate) the solid‐state heat capacity was also measured starting from room temperature. Several samples of each polymer were used so that average values of heat capacities could be established (reported in 10°K intervals). The data revealed for all polymers a nearly linear increase of heat capacity with increasing temperature over the whole temperature range investigated.