This paper proposes a bridgeless-type ac-side continuous-conduction-mode (CCM) current-source (CS) charge-pump (CP) power-factor-correction (PFC) electronic ballast. The drawbacks of conventional dc-side discontinuous-conduction-mode (DCM) electronic ballasts include high di/dt, high current stress, and high switching losses. As a result, conventional dc-side DCM CS-CP-PFC electronic ballasts have low efficiency, due to the DCM operation, and the ballasts require a large input electromagnetic interference filter. Conventional dc-side CCM CS-CP-PFC electronic ballasts are able to solve these problems, but still require a higher component count. To efficiently reduce the cost of electronic components, a bridgeless-type ac-side CCM CS-CP-PFC electronic ballast is proposed. A 32-W rated power electronic ballast prototype circuit is designed and implemented. Experimental results verify that the input-current harmonics meet the IEC 61000-3-2 Class-C Standard, and the CP capacitor helps the PFC inductor current to achieve CCM and high power factor
No takes yet. Share an insight, caveat, or question.
Lin et al. (2007) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: