It is demonstrated that materials with comparable thermal dependence of coercivity under normal laboratory measurement conditions, differing only in sign, have quite different properties at recording frequencies. Barium ferrites, with positive dH/sub c//dT, have augmented thermal dependence, whereas oxides with negative dH/sub c//dT exhibit weaker thermal dependence at recording frequencies. Experimental data and theoretical analysis confirm this behavior. Two methods of predicting coercivity as a function of temperature, for recording time scales, are presented. The implications for direct overwrite performance while thermally cycling are discussed.>
No takes yet. Share an insight, caveat, or question.
Meichle et al. (1992) studied this question.