A survey of various measurement techniques, including the rotation method, the hard-axis hysteresis loop, and the torque measurement, is presented using Co∕Pt multilayer recording media. It is found that for highly exchange-coupled samples, the results from the rotational method are consistent with those from the hard-axis hysteresis loop and torque measurements. Such anisotropy measurements are applied to determine the interfacial anisotropy in Co∕Pt multilayers (MLs) by studying a series of Co∕Pt ML samples with Co thickness ranging from 0.1 to 2 nm. The Pt thickness is fixed at either 1 or 0.5 nm. It is found that the multilayer with 1 nm Pt layer shows a larger interfacial anisotropy constant (KS∼0.8erg∕cm2) than the media with 0.5 nm Pt layer (KS∼0.6erg∕cm2), corresponding to about 80% and 60% of the interfacial anisotropy of the ML made by molecular-beam epitaxy, respectively [D. Weller et al., Mater. Res. Soc. Symp. Proc. 313, 791 (1993)]. Such thickness dependence is supported by the x-ray-diffraction superlattice peak measurements that indicate the discontinuous growth for the case with thinner Pt.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: