Insulation design with discharge simulation based on physics phenomena is used in designing electrical instruments to facilitate their miniaturization and get high insulation reliability. We developed a partial discharge inception calculation model in a non-uniform air gap based on theories of electron avalanche and streamer phenomena. The calculated and experimental PDIVs were compared under a constant humidity condition, and we confirmed these agreed well with each other within about 10 %. Furthermore, we built a relationship between negative ions and humidity into the model, and confirmed the calculated and experimental PDIVs (Partial Discharge Inception Voltage) agreed within about 15 %. Therefore, this model was judged as a method for predicting changes in PDIV when the humidity changes.