We measured the transmission of tapered and untapered optical fibres as a function of input beam numerical aperture at 635 nm. The tapered fibres were fabricated with an adiabatic tapering process from graded and step-index fibres with 50 μm core diameters to form a 100 mm long taper with 5:1 taper ratio. We tested tapered graded-index and step-index fibres fabricated from commercial Thorlabs products and a custom graded-index taper. The 5:1 tapered graded-index fibre can give a transmission greater than 0.4 for Thorlabs and 0.6 for the custom taper. We simulated the transmission of the tapered fibres and found reasonable agreement with the measured graded-index tapered fibre results across the numerical aperture range of interest. Experimentally, step-index tapered fibres performed relative poorly and considerably below modelling expectations. Based on our examinations this arises because the properties of step-index fibre were not robust to the tapering process. Suitably tapered graded-index fibres may offer a new route for efficient focal ratio reduction of fibre optic signals, e.g., in fibre-fed spectrographs, though we stress that our measurements have been limited to monochromatic light in this work.
No takes yet. Share an insight, caveat, or question.
Choochalerm et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: