Why the study?
Does high-angle compression hip screw fixation improve outcomes in subtrochanteric fractures?
Does high-angle compression hip screw fixation improve outcomes in subtrochanteric fractures?
High-angle compression hip screws provide efficient fixation for subtrochanteric fractures, enabling rapid mobilization and early partial weight-bearing.
May support high-angle screw fixation in subtrochanteric fractures; hypothesis-generating and requires prospective trials before practice change.
In a series of 25 subtrochanteric fractures transfixed with high-angle compression hip screws, there were no mechanical failures, delayed unions, or nonunions. Osseous union occurred in a mean time of 3.6 months. Malunion occurred in two instances, at least one of which was the result of technical error at the time of reduction. Rapid mobilization of patients with subtrochanteric fractures is an attainable goal. Early partial weight-bearing should be possible. Although no one internal fixation appliance may be optimal for all fractures in the subtrochanteric region, the high-angle compression hip screw is efficient for the fixation of a wide variety of fracture patterns that otherwise would have been difficult to manage.
No takes yet. Share an insight, caveat, or question.
Wile et al. (1983) studied this question.